Current Transducer HX 05..15-NP
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 5 .. 15 A
All data are given with RL = 10 kW
Electrical data
Primary nominal
current rms
IPN (A)
Primary current
measuring range
IPM (A)
Serial Parallel
Serial
± 5
± 10
± 15
VOUT
ROUT
RL
VC
VC
± 10
± 20
± 30
± 15
± 30
± 45
Parallel
± 30
± 60
± 90
Features
Primary conductor
Type
diameter x turns
(mm)
HX 05-NP
HX 10-NP
HX 15-NP
0.8d x (6T+6T)
1.0d x (3T+3T)
1.2d x (2T+2T)
Output voltage (Anarog) @ ± IPN, RL = 10 kW, TA = 25 °C
Output internal resistance
Load resistance
Supply voltage (± 5 %) 1)
Current consumption
± 4
< 50
≥ 10
± 15
< ± 15
V
W
kW
V
mA
Accuracy - Dynamic performance data
X
Accuracy @ IPN , TA = 25°C (xcluding offset)
3
Primary 1 to primary 2
> 1
Partial discharge extinction voltage rms @ 10 pC
≥ 1
Impulse withstand voltage 1.2/50 µs
≥ 6
Creepage distance
Clearance distance
Comparative Tracking Index (group I)
≥ 5.5
≥ 5.5
≥ 600
kV
kV
kV
kV
mm
mm
Applications examples
According to EN 50178 and IEC 61010-1 standards and following conditions:
●● Over voltage category OV 3
●● Pollution degree PD2
●● Non-uniform field
dCp, dCI,Vw
EN 50178
IEC 61010-1
Rated insulation voltage
Nominal voltage
Basic insulation
600 V
600 V
Reinforced insulation
300 V
150 V
Safety
This transducer must be used in electric/electronic equipment with respect
to applicable standards and safety requirements in accordance with the
manufacturer’s operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
110525/9 .
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Dimensions HX 05..15-NP (in mm. 1 mm = 0.0394 inch)
19 Max.
Terminal Pin Identification
15.4 Max.
20 Max.
1...... -15V
2...... 0V
3...... +15V
4...... Output
0.5
5...... Primary 1 input Current(-)
7...... Primary 1 input Current(+)
6...... Primary 2 input Current(-)
8...... Primary 2 input Current(+)
d
4
3.5+/-0.5
10.85
OUT
3
+V
0
2
3.5
1 -V or 0
3
Top view
6
8
7
5
HX 05-NP
CN2
6
4
4.5
P=2.54
6
410123
41123
10.85
4
Lot No.
Primary conductor diameter
HX
HX 05-NP
05-NP10-NP
10-NP
dd
0.8
0.8
1.0 1.0
15-NP
1.2
Secondary pins dimension
0.5 x 0.25
Mechanical characteristics
●● General tolerance
± 0.5 mm
Page 3/3
110525/9 .
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
很抱歉,暂时无法提供与“HX 10-NP”相匹配的价格&库存,您可以联系我们找货