HX 10-NP

HX 10-NP

  • 厂商:

    LEM(莱姆)

  • 封装:

  • 描述:

    LEM - HX 10-NP - Current Transducer, HX Series, PCB, 10A, -30A to 30A, 1 %, Voltage Output, 15 Vdc

  • 数据手册
  • 价格&库存
HX 10-NP 数据手册
Current Transducer HX 05..15-NP For the electronic measurement of currents: DC, AC, pulsed, mixed, with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 5 .. 15 A All data are given with RL = 10 kW Electrical data Primary nominal current rms IPN (A) Primary current measuring range IPM (A) Serial Parallel Serial ± 5 ± 10 ± 15 VOUT ROUT RL VC VC ± 10 ± 20 ± 30 ± 15 ± 30 ± 45 Parallel ± 30 ± 60 ± 90 Features Primary conductor Type diameter x turns (mm) HX 05-NP HX 10-NP HX 15-NP 0.8d x (6T+6T) 1.0d x (3T+3T) 1.2d x (2T+2T) Output voltage (Anarog) @ ± IPN, RL = 10 kW, TA = 25 °C Output internal resistance Load resistance Supply voltage (± 5 %) 1) Current consumption ± 4 < 50 ≥ 10 ± 15 < ± 15 V W kW V mA Accuracy - Dynamic performance data X Accuracy @ IPN , TA = 25°C (xcluding offset) 3 Primary 1 to primary 2 > 1 Partial discharge extinction voltage rms @ 10 pC ≥ 1 Impulse withstand voltage 1.2/50 µs ≥ 6 Creepage distance Clearance distance Comparative Tracking Index (group I) ≥ 5.5 ≥ 5.5 ≥ 600 kV kV kV kV mm mm Applications examples According to EN 50178 and IEC 61010-1 standards and following conditions: ●● Over voltage category OV 3 ●● Pollution degree PD2 ●● Non-uniform field dCp, dCI,Vw EN 50178 IEC 61010-1 Rated insulation voltage Nominal voltage Basic insulation 600 V 600 V Reinforced insulation 300 V 150 V Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 110525/9 . LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Dimensions HX 05..15-NP (in mm. 1 mm = 0.0394 inch) 19 Max. Terminal Pin Identification 15.4 Max. 20 Max. 1...... -15V 2...... 0V 3...... +15V 4...... Output 0.5 5...... Primary 1 input Current(-) 7...... Primary 1 input Current(+) 6...... Primary 2 input Current(-) 8...... Primary 2 input Current(+) d 4 3.5+/-0.5 10.85 OUT 3 +V 0 2 3.5 1 -V or 0 3 Top view 6 8 7 5 HX 05-NP CN2 6 4 4.5 P=2.54 6 410123 41123 10.85 4 Lot No. Primary conductor diameter HX HX 05-NP 05-NP10-NP 10-NP dd 0.8 0.8 1.0 1.0 15-NP 1.2 Secondary pins dimension 0.5 x 0.25 Mechanical characteristics ●● General tolerance ± 0.5 mm Page 3/3 110525/9 . LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com
HX 10-NP 价格&库存

很抱歉,暂时无法提供与“HX 10-NP”相匹配的价格&库存,您可以联系我们找货

免费人工找货
HX 10-NP

    库存:198

    HX 10-NP
    •  国内价格
    • 1+144.00551
    • 10+141.26469
    • 25+138.51201
    • 50+136.58988
    • 100+117.13128
    • 500+97.67268

    库存:209

    HX 10-NP
      •  国内价格
      • 1+127.61116
      • 25+122.74790
      • 50+121.04003

      库存:27